Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.451
1.
bioRxiv ; 2024 Apr 09.
Article En | MEDLINE | ID: mdl-38645137

Alpha-synuclein (αsyn) is an intrinsically disordered protein that aggregates in the brain in several neurodegenerative diseases collectively called synucleinopathies. Phosphorylation of αsyn at serine 129 (PSER129) was considered rare in the healthy human brain but is enriched in pathological αsyn aggregates and is used as a specific marker for disease inclusions. However, recent observations challenge this assumption by demonstrating that PSER129 results from neuronal activity and can be readily detected in the non-diseased mammalian brain. Here, we investigated experimental conditions under which two distinct PSER129 pools, namely endogenous-PSER129 and aggregated-PSER129, could be detected and differentiated in the mammalian brain. Results showed that in the wild-type (WT) mouse brain, perfusion fixation conditions greatly influenced the detection of endogenous-PSER129, with endogenous-PSER129 being nearly undetectable after delayed perfusion fixation (30-minute and 1-hour postmortem interval). Exposure to anesthetics (e.g., Ketamine or xylazine) before perfusion did not significantly influence endogenous-PSER129 detection or levels. In situ, non-specific phosphatase calf alkaline phosphatase (CIAP) selectively dephosphorylated endogenous-PSER129 while αsyn preformed fibril (PFF)-seeded aggregates and genuine disease aggregates (Lewy pathology and Papp-Lantos bodies in Parkinson's disease and multiple systems atrophy brain, respectively) were resistant to CIAP-mediated dephosphorylation. The phosphatase resistance of aggregates was abolished by sample denaturation, and CIAP-resistant PSER129 was closely associated with proteinase K (PK)-resistant αsyn (i.e., a marker of aggregation). CIAP pretreatment allowed for highly specific detection of seeded αsyn aggregates in a mouse model that accumulates non-aggregated-PSER129. We conclude that αsyn aggregates are impervious to phosphatases, and CIAP pretreatment increases detection specificity for aggregated-PSER129, particularly in well-preserved biological samples (e.g., perfusion fixed or flash-frozen mammalian tissues) where there is a high probability of interference from endogenous-PSER129. Our findings have important implications for the mechanism of PSER129-accumulation in the synucleinopathy brain and provide a simple experimental method to differentiate endogenous-from aggregated PSER129.

2.
Phys Rev Lett ; 132(14): 141901, 2024 Apr 05.
Article En | MEDLINE | ID: mdl-38640399

Using e^{+}e^{-} collision data corresponding to an integrated luminosity of 7.33 fb^{-1} recorded by the BESIII detector at center-of-mass energies between 4.128 and 4.226 GeV, we present an analysis of the decay D_{s}^{+}→π^{+}π^{-}e^{+}ν_{e}, where the D_{s}^{+} is produced via the process e^{+}e^{-}→D_{s}^{*±}D_{s}^{∓}. We observe the f_{0}(980) in the π^{+}π^{-} system and the branching fraction of the decay D_{s}^{+}→f_{0}(980)e^{+}ν_{e} with f_{0}(980)→π^{+}π^{-} measured to be (1.72±0.13_{stat}±0.10_{syst})×10^{-3}, where the uncertainties are statistical and systematic, respectively. The dynamics of the D_{s}^{+}→f_{0}(980)e^{+}ν_{e} decay are studied with the simple pole parametrization of the hadronic form factor and the Flatté formula describing the f_{0}(980) in the differential decay rate, and the product of the form factor f_{+}^{f_{0}}(0) and the c→s Cabibbo-Kobayashi-Maskawa matrix element |V_{cs}| is determined for the first time to be f_{+}^{f_{0}}(0)|V_{cs}|=0.504±0.017_{stat}±0.035_{syst}. Furthermore, the decay D_{s}^{+}→f_{0}(500)e^{+}ν_{e} is searched for the first time but no signal is found. The upper limit on the branching fraction of D_{s}^{+}→f_{0}(500)e^{+}ν_{e}, f_{0}(500)→π^{+}π^{-} decay is set to be 3.3×10^{-4} at 90% confidence level.

3.
Phys Rev Lett ; 132(15): 151903, 2024 Apr 12.
Article En | MEDLINE | ID: mdl-38682963

We perform a study of the χ_{c1}(3872) line shape using the data samples of e^{+}e^{-}→γχ_{c1}(3872), χ_{c1}(3872)→D^{0}D[over ¯]^{0}π^{0}, and π^{+}π^{-}J/ψ collected with the BESIII detector. The effects of the coupled channels and the off-shell D^{*0} are included in the parametrization of the line shape. The line shape mass parameter is obtained to be M_{X}=(3871.63±0.13_{-0.05}^{+0.06}) MeV. Two poles are found on the first and second Riemann sheets corresponding to the D^{*0}D[over ¯]^{0} branch cut. The pole location on the first sheet is much closer to the D^{*0}D[over ¯]^{0} threshold than the other, and is determined to be 7.04±0.15_{-0.08}^{+0.07} MeV above the D^{0}D[over ¯]^{0}π^{0} threshold with an imaginary part -0.19±0.08_{-0.19}^{+0.14} MeV.

4.
Phys Rev Lett ; 132(9): 091802, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38489649

By analyzing 7.33 fb^{-1} of e^{+}e^{-} annihilation data collected at center-of-mass energies between 4.128 and 4.226 GeV with the BESIII detector, we report the observation of the semileptonic decay D_{s}^{+}→η^{'}µ^{+}ν_{µ}, with a statistical significance larger than 10σ, and the measurements of the D_{s}^{+}→ηµ^{+}ν_{µ} and D_{s}^{+}→η^{'}µ^{+}ν_{µ} decay dynamics for the first time. The branching fractions of D_{s}^{+}→ηµ^{+}ν_{µ} and D_{s}^{+}→η^{'}µ^{+}ν_{µ} are determined to be (2.235±0.051_{stat}±0.052_{syst})% and (0.801±0.055_{stat}±0.028_{syst})%, respectively, with precision improved by factors of 6.0 and 6.6 compared to the previous best measurements. Combined with the results for the decays D_{s}^{+}→ηe^{+}ν_{e} and D_{s}^{+}→η^{'}e^{+}ν_{e}, the ratios of the decay widths are examined both inclusively and in several ℓ^{+}ν_{ℓ} four-momentum transfer ranges. No evidence for lepton flavor universality violation is found within the current statistics. The products of the hadronic form factors f_{+,0}^{η^{(')}}(0) and the c→s Cabibbo-Kobayashi-Maskawa matrix element |V_{cs}| are determined. The results based on the two-parameter series expansion are f_{+,0}^{η}(0)|V_{cs}|=0.452±0.010_{stat}±0.007_{syst} and f_{+,0}^{η^{'}}(0)|V_{cs}|=0.504±0.037_{stat}±0.012_{syst}, which help to constrain present models on f_{+,0}^{η^{(')}}(0). The forward-backward asymmetries are determined to be ⟨A_{FB}^{η}⟩=-0.059±0.031_{stat}±0.005_{syst} and ⟨A_{FB}^{η^{'}}⟩=-0.064±0.079_{stat}±0.006_{syst} for the first time, which are consistent with the theoretical calculation.

5.
J Hosp Infect ; 147: 77-82, 2024 Mar 15.
Article En | MEDLINE | ID: mdl-38492645

OBJECTIVES: There is limited data on the effects of discontinuing single-room isolation while maintaining contact precautions, such as the use of gowns and gloves. In April 2021, our hospital ceased single-room isolation for patients with vancomycin-resistant enterococci (VRE) because of single-room unavailability. This study assessed the impact of this policy by examining the incidence of hospital-acquired VRE bloodstream infections (HA-VRE BSI). METHODS: This retrospective quasi-experimental study was conducted at a tertiary-care hospital in Seoul, South Korea. Time-series analysis was used to evaluate HA-VRE BSI incidence at the hospital level and in the haematology unit before (phase 1) and after (phase 2) the policy change. RESULTS: At the hospital level, HA-VRE BSI incidence level (VRE BSI per 1000 patient-days per month) and trend did not change significantly between phase 1 and phase 2 (coefficient -0.015, 95% confidence interval (CI): -0.053 to 0.023, P=0.45 and 0.000, 95% CI: -0.002 to 0.002, P=0.84, respectively). Similarly, HA-VRE BSI incidence level and trend in the haematology unit (-0.285, 95% CI: -0.618 to 0.048, P=0.09 and -0.018, 95% CI: -0.036 to 0.000, P = 0.054, respectively) did not change significantly across the two phases. CONCLUSIONS: Discontinuing single-room isolation of VRE-colonized or infected patients was not associated with an increase in the incidence of VRE BSI at the hospital level or among high-risk patients in the haematology unit. Horizontal intervention for multi-drug-resistant organisms, including measures such as enhanced hand hygiene and environmental cleaning, may be more effective at preventing VRE transmission.

6.
Phys Rev Lett ; 132(8): 081904, 2024 Feb 23.
Article En | MEDLINE | ID: mdl-38457707

Based on data samples collected with the BESIII detector at the BEPCII collider, the process e^{+}e^{-}→Σ^{+}Σ[over ¯]^{-} is studied at center-of-mass energies sqrt[s]=2.3960, 2.6454, and 2.9000 GeV. Using a fully differential angular description of the final state particles, both the relative magnitude and phase information of the Σ^{+} electromagnetic form factors in the timelike region are extracted. The relative phase between the electric and magnetic form factors is determined to be sinΔΦ=-0.67±0.29(stat)±0.18(syst) at sqrt[s]=2.3960 GeV, ΔΦ=55°±19°(stat)±14°(syst) at sqrt[s]=2.6454 GeV, and 78°±22°(stat)±9°(syst) at sqrt[s]=2.9000 GeV. For the first time, the phase of the hyperon electromagnetic form factors is explored in a wide range of four-momentum transfer. The evolution of the phase along with four-momentum transfer is an important input for understanding its asymptotic behavior and the dynamics of baryons.

7.
Phys Rev Lett ; 132(3): 031801, 2024 Jan 19.
Article En | MEDLINE | ID: mdl-38307076

Based on 4.4 fb^{-1} of e^{+}e^{-} annihilation data collected at the center-of-mass energies between 4.60 and 4.70 GeV with the BESIII detector at the BEPCII collider, the pure W-boson-exchange decay Λ_{c}^{+}→Ξ^{0}K^{+} is studied with a full angular analysis. The corresponding decay asymmetry is measured for the first time to be α_{Ξ^{0}K^{+}}=0.01±0.16(stat)±0.03(syst). This result reflects the noninterference effect between the S- and P-wave amplitudes. The phase shift between S- and P-wave amplitudes has two solutions, which are δ_{p}-δ_{s}=-1.55±0.25(stat)±0.05(syst) rad or 1.59±0.25(stat)±0.05(syst) rad.

8.
Clin Radiol ; 79(4): 263-271, 2024 Apr.
Article En | MEDLINE | ID: mdl-38220515

AIM: To investigate the diagnostic performance of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) for thymic epithelial tumours (TETs) and the complication rate after PTNB including seeding after PTNB. MATERIALS AND METHODS: This retrospective study identified PTNBs for anterior mediastinal lesions between May 2007 and September 2021. The diagnostic performance for TETs and complications were investigated. The concordance of the histological grades of TETs between PTNB and surgery was evaluated. The factors associated with pleural seeding after PTNB were determined using Cox regression analysis. RESULTS: Of 387 PTNBs, 235 PTNBs from 225 patients diagnosed as TETs (124 thymomas and 101 thymic carcinomas) and 150 PTNBs from 133 patients diagnosed as other than TETs were included. The sensitivity, specificity, and accuracy for TETs were 89.4% (210/235), 100% (210/210), and 93.5% (360/385), respectively, with an immediate complication rate of 4.4% (17/385). The concordance rate of the histological grades between PTNB and surgery was 73.3% (77/105) after excluding uncategorised types of thymomas. During follow-up after PTNB (median duration, 38.8 months; range, 0.3-164.6 months), no tract seeding was observed. Pleural seeding was observed in 26 patients. Thymic carcinoma (hazard ratio [HR], 5.94; 95% confidence interval [CI], 2.07-17.08; p=0.001) and incomplete resection (HR, 3.29; 95% CI, 1.20-9.02; p=0.02) were associated with pleural seeding, while the biopsy approach type (transpleural versus parasternal) was not associated (p=0.12). CONCLUSIONS: Pretreatment biopsy for TETs was accurate and safe and may be considered for diagnosing TETs, particularly when the diagnosis is challenging and histological diagnosis is mandatory.


Neoplasms, Glandular and Epithelial , Thymoma , Thymus Neoplasms , Humans , Thymoma/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods , Biopsy, Needle/methods , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Thymus Neoplasms/diagnostic imaging , Neoplasms, Glandular and Epithelial/diagnostic imaging
9.
Clin Radiol ; 79(1): e182-e188, 2024 Jan.
Article En | MEDLINE | ID: mdl-37925364

AIM: To analyse the clinicoradiological characteristics of traumatic inferior vena cava (IVC) injury level on preoperative computed tomography (CT). MATERIALS AND METHODS: This retrospective study evaluated patients from a single trauma centre treated for traumatic IVC injury between January 2014 and January 2021. Data on demographics, mechanism of injury, Injury Severity Score, radiological findings on CT and angiography, IVC injury level in surgical findings, complications, and clinical outcomes were collected. RESULTS: During the 8-year study period, 36 patients presented with traumatic IVC injury: 19 underwent preoperative CT with 17 (89%) blunt and two (11%) penetrating injuries. The most common primary CT sign was contour abnormality (53%, n=10), followed by intraluminal flap and active extravasation (21%, n=4). Among the secondary signs, hepatic laceration (53%, n=10) and retroperitoneal haemorrhage (53%, n=10) were the most common. Frequencies of primary and secondary signs were higher in the infrarenal and suprarenal than in the retrohepatic vena cava injuries. Diagnostic capability of preoperative CT for IVC injury differed according to the IVC level. The detection rate was the highest for an infrarenal vena cava injury at 100% (n=4), followed by that for a suprarenal, suprahepatic, and retrohepatic vena cava injuries at 75% (n=3), 43% (n=3), and 25% (n=1), respectively. CONCLUSION: CT findings of traumatic IVC injuries may vary depending on the mechanism and anatomical site of injury. Familiarity with IVC injury imaging features may help in diagnosis and surgical treatment planning.


Abdominal Injuries , Vascular System Injuries , Humans , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/injuries , Retrospective Studies , Trauma Centers , Liver/diagnostic imaging , Vascular System Injuries/diagnostic imaging , Tomography, X-Ray Computed
10.
Phys Rev Lett ; 131(21): 211801, 2023 Nov 24.
Article En | MEDLINE | ID: mdl-38072600

The first simultaneous determination of the absolute value of the Cabibbo-Kobayashi-Maskawa matrix element V_{ub} using inclusive and exclusive decays is performed with the full Belle data set at the ϒ(4S) resonance, corresponding to an integrated luminosity of 711 fb^{-1}. We analyze collision events in which one B meson is fully reconstructed in hadronic modes. This allows for the reconstruction of the hadronic X_{u} system of the semileptonic b→uℓν[over ¯]_{ℓ} decay. We separate exclusive B→πℓν[over ¯]_{ℓ} decays from other inclusive B→X_{u}ℓν[over ¯]_{ℓ} and backgrounds with a two-dimensional fit that utilizes the number of charged pions in the X_{u} system and the four-momentum transfer q^{2} between the B and X_{u} systems. Combining our measurement with information from lattice QCD and QCD calculations of the inclusive partial rate as well as external experimental information on the shape of the B→πℓν[over ¯]_{ℓ} form factor, we determine |V_{ub}^{excl}|=(3.78±0.23±0.16±0.14)×10^{-3} and |V_{ub}^{incl}|=(3.88±0.20±0.31±0.09)×10^{-3}, respectively, with the uncertainties being the statistical error, systematic errors, and theory errors. The ratio of |V_{ub}^{excl}|/|V_{ub}^{incl}|=0.97±0.12 is compatible with unity.

11.
Phys Rev Lett ; 131(21): 211802, 2023 Nov 24.
Article En | MEDLINE | ID: mdl-38072609

We report on a search for a heavy Majorana neutrino in the decays τ^{-}→π^{-}ν_{h}, ν_{h}→π^{±}ℓ^{∓}, ℓ=e, µ. The results are obtained using the full data sample of 988 fb^{-1} collected with the Belle detector at the KEKB asymmetric energy e^{+}e^{-} collider, which contains 912×10^{6} ττ pairs. We observe no significant signal and set 95% CL upper limits on the couplings of the heavy right-handed neutrinos to the conventional standard model left-handed neutrinos in the mass range 0.2-1.6 GeV/c^{2}. This is the first study of a mixed couplings of heavy neutrinos to τ leptons and light-flavor leptons.

12.
Phys Rev Lett ; 131(20): 201802, 2023 Nov 17.
Article En | MEDLINE | ID: mdl-38039466

We search for energetic electron recoil signals induced by boosted dark matter (BDM) from the galactic center using the COSINE-100 array of NaI(Tl) crystal detectors at the Yangyang Underground Laboratory. The signal would be an excess of events with energies above 4 MeV over the well-understood background. Because no excess of events are observed in a 97.7 kg·yr exposure, we set limits on BDM interactions under a variety of hypotheses. Notably, we explored the dark photon parameter space, leading to competitive limits compared to direct dark photon search experiments, particularly for dark photon masses below 4 MeV and considering the invisible decay mode. Furthermore, by comparing our results with a previous BDM search conducted by the Super-Kamionkande experiment, we found that the COSINE-100 detector has advantages in searching for low-mass dark matter. This analysis demonstrates the potential of the COSINE-100 detector to search for MeV electron recoil signals produced by the dark sector particle interactions.

13.
Malays Orthop J ; 17(3): 48-58, 2023 Nov.
Article En | MEDLINE | ID: mdl-38107359

Introduction: The current standard treatment for ankle syndesmosis injury is static screw fixation. Dynamic fixation was developed to restore the dynamic function of the syndesmosis. The purpose of this study was to determine that which of static screw fixation and dynamic fixation is better for treatment of ankle syndesmosis injury in pronation-external rotation fractures. Materials and methods: Thirty patients were treated with dynamic fixation (DF group) and 28 patients with static screw fixation (SF group). The primary outcome was Olerud-Molander Ankle Outcome Score. The secondary outcome were Visual Analogue Scale score and American Orthopedic Foot and Ankle Society score, radiographic outcomes, complications and cost effectiveness. To evaluate the radiographic outcome, the tibiofibular clear space, tibiofibular overlap, and medial clear space were compared using the pre-operative and last follow-up plain radiographs. To evaluate the cost effectiveness, the total hospital cost was compared between the two groups. Results: There was no significant difference in primary outcome. Moreover, there were no significant difference in secondary outcome including Visual Analogue Scale score and American Orthopedic Foot and Ankle Society score and radiographic outcome. Two cases of reduction loss and four cases of screw breakage were observed in the SF group. No complication in the DF group was observed. Dynamic fixation was more cost effective than static screw fixation with respect to the total hospital cost. Conclusion: Although dynamic fixation provided similar clinical and radiologic outcome, dynamic fixation is more cost effective with fewer complications than static screw fixation in ankle syndesmosis injury of pronation-external rotation fractures.

14.
Public Health ; 225: 1-7, 2023 Dec.
Article En | MEDLINE | ID: mdl-37913609

OBJECTIVE: We estimated the impact of the changes made to the Public Charge Rule on the initiation of prenatal care among uninsured immigrants in the United States. STUDY DESIGN: We used a difference-in-differences approach to analyse the impact of the changes made to the Public Charge Rule (first difference) on initiation of prenatal care between uninsured and privately insured immigrants (second difference). METHODS: We used the natality data by the National Center for Health Statistics as the main data source, which includes all singleton births in a hospital to an immigrant birthing person aged from 15 to 44. The study covers three phases: (1) the period prior to the leaked draft Executive Orders concerning changes made to the public charge policy-from January 2014 to December 2016; (2) the period after the draft Executive Orders were leaked until the proposal of the Public Charge Rule-from January 2017 to September 2018; and (3) post proposal of the Public Charge Rule -from October 2018 to December 2019. RESULTS: After the proposal of the Public Charge Rule in 2018, the odds of initiating prenatal care in the first trimester decreased among uninsured immigrants by 12% (odds ratio [OR]: 0.880; 95% confidence interval [CI]: 0.832, 0.931) compared to privately insured immigrants. The odds of second trimester initiation of prenatal care was also negatively associated with the leak of the draft Executive Orders (OR: 0.942; 95% CI: 0.905, 0.981). CONCLUSION: The results of this study suggest that uninsured immigrants in the United States significantly delayed prenatal care after the changes were made to the Public Charge Rule.


Emigrants and Immigrants , Medically Uninsured , Pregnancy , Female , Humans , United States , Prenatal Care , Insurance, Health , Public Policy
15.
Phys Rev Lett ; 131(19): 191901, 2023 Nov 10.
Article En | MEDLINE | ID: mdl-38000396

We study the process e^{+}e^{-}→Λ_{c}^{+}Λ[over ¯]_{c}^{-} at twelve center-of-mass energies from 4.6119 to 4.9509 GeV using data samples collected by the BESIII detector at the BEPCII collider. The Born cross sections and effective form factors (|G_{eff}|) are determined with unprecedented precision after combining the single and double-tag methods based on the decay process Λ_{c}^{+}→pK^{-}π^{+}. Flat cross sections around 4.63 GeV are obtained and no indication of the resonant structure Y(4630), as reported by Belle, is found. In addition, no oscillatory behavior is discerned in the |G_{eff}| energy dependence of Λ_{c}^{+}, in contrast to what is seen for the proton and neutron cases. Analyzing the cross section together with the polar-angle distribution of the Λ_{c}^{+} baryon at each energy point, the moduli of electric and magnetic form factors (|G_{E}| and |G_{M}|) are extracted and separated. For the first time, the energy dependence of the form factor ratio |G_{E}/G_{M}| is observed, which can be well described by an oscillatory function.

16.
Phys Rev Lett ; 131(15): 151901, 2023 Oct 13.
Article En | MEDLINE | ID: mdl-37897776

A narrow structure in the pΛ[over ¯] system near the mass threshold, named as X(2085), is observed in the process e^{+}e^{-}→pK^{-}Λ[over ¯] with a statistical significance greater than 20σ. Its spin and parity are determined for the first time to be J^{P}=1^{+} in an amplitude analysis, with a statistical significance greater than 5σ over other quantum numbers (0^{-},1^{-} and 2^{+}). The pole positions of X(2085) are measured to be M_{pole}=(2084_{-2}^{+4}±9) MeV and Γ_{pole}=(58_{-3}^{+4}±25) MeV, where the first uncertainties are statistical and the second ones are systematic. The analysis is based on the study of the process e^{+}e^{-}→pK^{-}Λ[over ¯] and uses the data samples collected with the BESIII detector at the center-of-mass energies sqrt[s]=4.008, 4.178, 4.226, 4.258, 4.416, and 4.682 GeV with a total integrated luminosity of 8.35 fb^{-1}.

17.
Phys Rev Lett ; 131(15): 151903, 2023 Oct 13.
Article En | MEDLINE | ID: mdl-37897771

The process e^{+}e^{-}→D_{s}^{*+}D_{s}^{*-} is studied with a semi-inclusive method using data samples at center-of-mass energies from threshold to 4.95 GeV collected with the BESIII detector operating at the Beijing Electron Positron Collider. The Born cross sections of the process are measured for the first time with high precision in this energy region. Two resonance structures are observed in the energy-dependent cross sections around 4.2 and 4.4 GeV. By fitting the cross sections with a coherent sum of three Breit-Wigner amplitudes and one phase-space amplitude, the two significant structures are assigned masses of (4186.8±8.7±30) and (4414.6±3.4±6.1) MeV/c^{2}, widths of (55±15±53) and (122.5±7.5±8.1) MeV, where the first errors are statistical and the second ones are systematic. The inclusion of a third Breit-Wigner amplitude is necessary to describe a structure around 4.79 GeV.

18.
Clin Radiol ; 78(12): e941-e949, 2023 12.
Article En | MEDLINE | ID: mdl-37788968

AIM: To investigate how magnetic resonance imaging (MRI) examinations are protocolled in tertiary paediatric neuroradiology centres around the UK for some of the more common presentations encountered in paediatric neuroradiology, and to identify any variations of note. MATERIALS AND METHODS: All 19 UK tertiary paediatric neuroradiology centres registered with the British Society of Neuroradiologists-Paediatric Group were contacted and asked if they could provide a copy of their standard MRI protocols. Twelve responded (63%) and 10 of the more common presentations were selected and the standard acquired sequences obtained at each participating centre were compared. Where available the collated protocols were also compared against current published guidance. RESULTS: The basic sequences carried out by centres around the UK are similar; however, there are lots of variations overall. The only standardised protocol currently being implemented nationally in paediatric imaging is that for brain tumours. Otherwise, chosen protocols are generally dependent on the preferences and technical capabilities of individual centres. Suggested published protocols also exist for non-accidental injury (NAI), multiple sclerosis, epilepsy, and head and neck imaging. CONCLUSIONS: The differences in MRI protocolling depend in part on technical capabilities and in part on the experience and preferences of the paediatric neuroradiologists at each centre. For most presentations, there is no consensus as to what constitutes the perfect protocol. The present results will be useful for specialist centres who may wish to review their current protocols, and for more generalist centres to use as a reference to guide their MRI protocolling.


Brain Neoplasms , Hospitals, Pediatric , Child , Humans , Brain Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Tertiary Care Centers , United Kingdom
19.
Phys Rev Lett ; 131(14): 141802, 2023 Oct 06.
Article En | MEDLINE | ID: mdl-37862669

Using 7.33 fb^{-1} of e^{+}e^{-} collision data taken with the BESIII detector at the BEPCII collider, we report the first experimental study of the purely leptonic decay D_{s}^{*+}→e^{+}ν_{e}. Our data contain a signal of this decay with a statistical significance of 2.9σ. The branching fraction of D_{s}^{*+}→e^{+}ν_{e} is measured to be (2.1_{-0.9_{stat}}^{+1.2}±0.2_{syst})×10^{-5}, corresponding to an upper limit of 4.0×10^{-5} at the 90% confidence level. Taking the total width of the D_{s}^{*+} [(0.070±0.028) keV] predicted with the radiative D_{s}^{*+} decay from the lattice QCD calculation as input, the decay constant of the D_{s}^{*+} is determined to be f_{D_{s}^{*+}}=(214_{-46_{stat}}^{+61}±44_{syst}) MeV, corresponding to an upper limit of 354 MeV at the 90% confidence level.

...